Q: I have started auditing on my AS/400 and I have a large volume of data collected in the audit journal receiver. Are there IBM programs available to generate reports and manage the audit journal?

A: Reporting and journal management have been left to the individual installation. I am unaware of any plans by IBM to add additional audit journal management or report generation tools. You can get some reporting support by creating the Display Audit Log (DSPAUDLOG) tool from the QUSRTOOL library. This tool merges the data from the audit journal with messages to make the journal entries understandable. You can see an example of the listing produced by the DSPAUDLOG command in 1.

A: Reporting and journal management have been left to the individual installation. I am unaware of any plans by IBM to add additional audit journal management or report generation tools. You can get some reporting support by creating the Display Audit Log (DSPAUDLOG) tool from the QUSRTOOL library. This tool merges the data from the audit journal with messages to make the journal entries understandable. You can see an example of the listing produced by the DSPAUDLOG command in Figure 1.

The prompt for the DSPAUDLOG command allows you to specify either a file name or *CURRENT. DSPAUDLOG will extract the data from the journal receiver when you use *CURRENT. When you specify a file name, you must use the Display Journal (DSPJRN) command to store the data in the file. Use keywords like STRDATE and ENDDATE to select data for specific dates or ENTTYP to select entries by their two-character journal entry codes. IBM describes the journal entry codes in the Security Reference Manual (SC41-3302). For more information about the DSPAUDLOG command, see From the Toolbox, elsewhere in this issue.

Q:When I use the audit journal, almost half of the entries are for objects in the QTEMP library. How can I eliminate these entries?

A: Currently, you can't. I have requested that IBM give users an option that would eliminate recording of the QTEMP library auditing data. Until that option is available, the audit journal will contain data from the QTEMP library.

I have found a useful technique to eliminate the unwanted QTEMP data from the reports. I create a logical file that eliminates them.

1. Create a database file to hold the data from the journal receiver. I use the

 CRTDUPOBJ OBJ(QASYAFJE) + OBJTYPE(*FILE) + FROMLIB(QSYS) TOLIB(your-lib) 

2. Using the DDS shown in 2, create a logical file that eliminates the QTEMP library entries-the library name must be specified in the PFILE keyword to avoid selecting the IBM file in library QSYS.

2. Using the DDS shown in Figure 2, create a logical file that eliminates the QTEMP library entries-the library name must be specified in the PFILE keyword to avoid selecting the IBM file in library QSYS.

3. Using the Display Journal (DSPJRN) command, copy data from the journal receiver into the database file created in step 1. The OUTFILFMT should always be *TYPE2 to match the file definition. You can select the data range using the FROMTIME and TOTIME keywords and the specific entry types using the ENTTYP keyword.

 DSPJRN JRN(QAUDJRN) JRNCDE(T) + OUTPUT(*OUTFILE) + OUTFILE(your-lib/QASYAFJE) + OUTFILFMT(*TYPE2) + FROMTIME(date time) + TOTIME(date time) + ENTTYP(up to ten entry types) 

4. Print the report using the DSPAUDLOG command from QUSRTOOL. By specifying the name of the logical file AUJ003L1, created in step 2, you eliminate the QTEMP library entries.

 DSPAUDLOG OPTION(AUJ003L1) + OUTPUT(*PRINT) 

Audit information can be lost when not reporting on the QTEMP library entries, because objects can be moved from QTEMP into production libraries.

This method of using a logical file to select specific entries can be used in other instances. The AF entry type includes several conditions. On occasion, I have wanted to produce reports for one of the violation types, such as domain failures. The system includes domain failure conditions with many other authority failure conditions. The DSPJRN and DSPAUDLOG commands do not support selection by the violation type field (position 156 of the record). However, you can use a logical file to select the domain failure entries. See the DDS to select the domain failures in 3.

This method of using a logical file to select specific entries can be used in other instances. The AF entry type includes several conditions. On occasion, I have wanted to produce reports for one of the violation types, such as domain failures. The system includes domain failure conditions with many other authority failure conditions. The DSPJRN and DSPAUDLOG commands do not support selection by the violation type field (position 156 of the record). However, you can use a logical file to select the domain failure entries. See the DDS to select the domain failures in Figure 3.

Q:Our auditors are concerned about the use of DFU to alter production files. We cannot prevent access to DFU because it is used to correct data files. Is there a way to audit the use of DFU from our menus?

A: You could audit the DFU command to determine who is using DFU, but that would not allow you to determine which files are referenced. I suspect that the auditors want to know which files or records are changed.

You can audit the use of DFU with the program DFA001CL, shown in 4. The program displays a screen (source shown in 5) that prompts the user to enter the name of the file to be modified using DFU. The program then records the records that are charged in the DFU journal. You must create the journal and journal receiver prior to using the program.

You can audit the use of DFU with the program DFA001CL, shown in Figure 4. The program displays a screen (source shown in Figure 5) that prompts the user to enter the name of the file to be modified using DFU. The program then records the records that are charged in the DFU journal. You must create the journal and journal receiver prior to using the program.

The Start Journal Physical File (STRJRNPF) and End Journal Physical File (ENDJRNPF) commands are the essential lines in the CL program. They allow you to track changes made to the file during the DFU session. However, anyone who changes the file in any way while the journal is on will be recorded. You can select only certain users when reviewing the journal.

You can ensure that users do not bypass auditing by removing *PUBLIC access from the STRDFU command. Grant *USE access to the STRDFU command to a profile like DFU_AUDIT. The program DFA001CL will need to adopt its owner's user profile DFU_AUDIT that has access to the STRDFU command.


Security Patrol: Security Questions & Answers

Figure 1 Sample DSPAUDLOG Output

 UNABLE TO REPRODUCE GRAPHICS 
Security Patrol: Security Questions & Answers

Figure 2 DDS to Hide Audit Records for QTEMP

 *=======================================================* * To compile: * * CRTLF FILE(XXX/AUJ003L1) SRCFILE(XXX/QDDSSRC) * * * *=======================================================* *. 1 ...+... 2 ...+... 3 ...+... 4 ...+... 5 ...+... 6 ...+... 7 A R QASYAFJE PFILE(YOURLIB/QASYAFJE) A K AFOLIB A S AFOLIB CMP(NE 'QTEMP') 
Security Patrol: Security Questions & Answers

Figure 3 DDS to Select Audit Records for Domain Failures

 *=======================================================* * To compile: * * CRTLF FILE(XXX/AUJ004L1) SRCFILE(XXX/QDDSSRC) * * * *=======================================================* *. 1 ...+... 2 ...+... 3 ...+... 4 ...+... 5 ...+... 6 ...+... 7 A R QASYAFJE PFILE(YOURLIB/QASYAFJE) A K AFVIOL A S AFVIOL CMP(EQ 'D') 
Security Patrol: Security Questions & Answers

Figure 4 DFA001CL CL Source

 /*===================================================================*/ /* To compile: */ /* CRTCLPGM PGM(XXX/DFA001CL) SRCFILE(XXX/QCLSRC) */ /* */ /*===================================================================*/ DFA001CL: + PGM DCLF FILE(DFA001D1) DCL VAR(&TEXT) TYPE(*CHAR) LEN(80) SNDRCVF CHKOBJ OBJ(&LIB/&FILE) OBJTYPE(*FILE) MONMSG MSGID(CPF0000) EXEC(GOTO CMDLBL(EXIT)) CHGVAR VAR(&TEXT) VALUE('DFU started for file ' + *CAT &LIB *TCAT '/' *CAT &FILE) SNDJRNE JRN(QAUDJRN) ENTDTA(&TEXT) STRJRNPF FILE(&LIB/&FILE) JRN(DFU) IMAGES(*BOTH) STRDFU OPTION(5) FILE(&LIB/&FILE) ENDJRNPF FILE(&LIB/&FILE) JRN(DFU) EXIT: ENDPGM 
Security Patrol: Security Questions & Answers

Figure 5 DFA001DF DDS Source

 *=============================================================== * To compile: * * CRTDSPF FILE(XXX/DFA001DF) SRCFILE(XXX/QDDSSRC) * *=============================================================== *. 1 ...+... 2 ...+... 3 ...+... 4 ...+... 5 ...+... 6 ...+... 7 A DSPSIZ(24 80 *DS3) A CA03 A R PROMPT A 2 26'Start DFU for Application File' A DSPATR(HI) A 6 3'Enter file name . . . . . . ' A FILE 10 I 6 32 A 7 5'Library . . . . . . . . .' A LIB 10 I 7 34 A 23 2'F3=Exit' A COLOR(BLU) 
BLOG COMMENTS POWERED BY DISQUS

LATEST COMMENTS

Support MC Press Online

$0.00 Raised:
$

Book Reviews

Resource Center

  • SB Profound WC 5536 Have you been wondering about Node.js? Our free Node.js Webinar Series takes you from total beginner to creating a fully-functional IBM i Node.js business application. You can find Part 1 here. In Part 2 of our free Node.js Webinar Series, Brian May teaches you the different tooling options available for writing code, debugging, and using Git for version control. Brian will briefly discuss the different tools available, and demonstrate his preferred setup for Node development on IBM i or any platform. Attend this webinar to learn:

  • SB Profound WP 5539More than ever, there is a demand for IT to deliver innovation. Your IBM i has been an essential part of your business operations for years. However, your organization may struggle to maintain the current system and implement new projects. The thousands of customers we've worked with and surveyed state that expectations regarding the digital footprint and vision of the company are not aligned with the current IT environment.

  • SB HelpSystems ROBOT Generic IBM announced the E1080 servers using the latest Power10 processor in September 2021. The most powerful processor from IBM to date, Power10 is designed to handle the demands of doing business in today’s high-tech atmosphere, including running cloud applications, supporting big data, and managing AI workloads. But what does Power10 mean for your data center? In this recorded webinar, IBMers Dan Sundt and Dylan Boday join IBM Power Champion Tom Huntington for a discussion on why Power10 technology is the right strategic investment if you run IBM i, AIX, or Linux. In this action-packed hour, Tom will share trends from the IBM i and AIX user communities while Dan and Dylan dive into the tech specs for key hardware, including:

  • Magic MarkTRY the one package that solves all your document design and printing challenges on all your platforms. Produce bar code labels, electronic forms, ad hoc reports, and RFID tags – without programming! MarkMagic is the only document design and print solution that combines report writing, WYSIWYG label and forms design, and conditional printing in one integrated product. Make sure your data survives when catastrophe hits. Request your trial now!  Request Now.

  • SB HelpSystems ROBOT GenericForms of ransomware has been around for over 30 years, and with more and more organizations suffering attacks each year, it continues to endure. What has made ransomware such a durable threat and what is the best way to combat it? In order to prevent ransomware, organizations must first understand how it works.

  • SB HelpSystems ROBOT GenericIT security is a top priority for businesses around the world, but most IBM i pros don’t know where to begin—and most cybersecurity experts don’t know IBM i. In this session, Robin Tatam explores the business impact of lax IBM i security, the top vulnerabilities putting IBM i at risk, and the steps you can take to protect your organization. If you’re looking to avoid unexpected downtime or corrupted data, you don’t want to miss this session.

  • SB HelpSystems ROBOT GenericCan you trust all of your users all of the time? A typical end user receives 16 malicious emails each month, but only 17 percent of these phishing campaigns are reported to IT. Once an attack is underway, most organizations won’t discover the breach until six months later. A staggering amount of damage can occur in that time. Despite these risks, 93 percent of organizations are leaving their IBM i systems vulnerable to cybercrime. In this on-demand webinar, IBM i security experts Robin Tatam and Sandi Moore will reveal:

  • FORTRA Disaster protection is vital to every business. Yet, it often consists of patched together procedures that are prone to error. From automatic backups to data encryption to media management, Robot automates the routine (yet often complex) tasks of iSeries backup and recovery, saving you time and money and making the process safer and more reliable. Automate your backups with the Robot Backup and Recovery Solution. Key features include:

  • FORTRAManaging messages on your IBM i can be more than a full-time job if you have to do it manually. Messages need a response and resources must be monitored—often over multiple systems and across platforms. How can you be sure you won’t miss important system events? Automate your message center with the Robot Message Management Solution. Key features include:

  • FORTRAThe thought of printing, distributing, and storing iSeries reports manually may reduce you to tears. Paper and labor costs associated with report generation can spiral out of control. Mountains of paper threaten to swamp your files. Robot automates report bursting, distribution, bundling, and archiving, and offers secure, selective online report viewing. Manage your reports with the Robot Report Management Solution. Key features include:

  • FORTRAFor over 30 years, Robot has been a leader in systems management for IBM i. With batch job creation and scheduling at its core, the Robot Job Scheduling Solution reduces the opportunity for human error and helps you maintain service levels, automating even the biggest, most complex runbooks. Manage your job schedule with the Robot Job Scheduling Solution. Key features include:

  • LANSA Business users want new applications now. Market and regulatory pressures require faster application updates and delivery into production. Your IBM i developers may be approaching retirement, and you see no sure way to fill their positions with experienced developers. In addition, you may be caught between maintaining your existing applications and the uncertainty of moving to something new.

  • LANSAWhen it comes to creating your business applications, there are hundreds of coding platforms and programming languages to choose from. These options range from very complex traditional programming languages to Low-Code platforms where sometimes no traditional coding experience is needed. Download our whitepaper, The Power of Writing Code in a Low-Code Solution, and:

  • LANSASupply Chain is becoming increasingly complex and unpredictable. From raw materials for manufacturing to food supply chains, the journey from source to production to delivery to consumers is marred with inefficiencies, manual processes, shortages, recalls, counterfeits, and scandals. In this webinar, we discuss how:

  • The MC Resource Centers bring you the widest selection of white papers, trial software, and on-demand webcasts for you to choose from. >> Review the list of White Papers, Trial Software or On-Demand Webcast at the MC Press Resource Center. >> Add the items to yru Cart and complet he checkout process and submit

  • Profound Logic Have you been wondering about Node.js? Our free Node.js Webinar Series takes you from total beginner to creating a fully-functional IBM i Node.js business application.

  • SB Profound WC 5536Join us for this hour-long webcast that will explore:

  • Fortra IT managers hoping to find new IBM i talent are discovering that the pool of experienced RPG programmers and operators or administrators with intimate knowledge of the operating system and the applications that run on it is small. This begs the question: How will you manage the platform that supports such a big part of your business? This guide offers strategies and software suggestions to help you plan IT staffing and resources and smooth the transition after your AS/400 talent retires. Read on to learn: